Cement Retained
Provide® Abutment
Indirect Technique
Non-Prepared Post
(continued from previous page)

13. Opaque, build porcelain, stain and glaze the crown.

Delivery Of Restoration
14. Remove the Provide Protection Cap or provisional crown from the abutment using cotton pliers. Try the crown on the Provide Abutment and check occlusion, marginal fit and interproximal contacts. Cement the crown onto the abutment.