Implant Retained
Fixed Prosthesis Standard Abutment Fixed
Hybrid
1.
Restorative Dentist Follow the steps for Standard Abutment
Impressions on pages 74-79 for the Pick-Up or Transfer
Technique.
2.
Laboratory Follow the steps on page 81 and 82 for
fabrication of the verification index, baseplate and wax
occlusal rim, wax try-in and plaster or silicone matrix.
or
Request a CAM StructSURE™ Precision
Milled Bar. See CAM StructSURE Manual (ART861)
3. Carefully remove the Standard Abutment Gold or
Castable Cylinders from the verification index. Place the
cylinders onto the analogs and attach with waxing screws using
a .048” Large Hex Driver. Adjust the height of the sleeves as
necessary. Wax the hybrid bar patterns to the waxing sleeves
and add acrylic resin retention to the top of the bar. Use the
matrix on the cast to position the bar within the confines of
the wax try-in.
4. Remove the hybrid bar wax up from the cast.
Invest, burnout and cast the bar in a semi-precious or high
noble alloy (see page 9 for casting alloy specifications).
Divest, finish and polish the under surface of the bar with
polishing protectors in place. Return the bar to the
restorative dentist for try in and fit
verification.