Implant Retained Fixed Prosthesis
Standard Abutment
Fixed Hybrid

1. Restorative Dentist
undefined Follow the steps for Standard Abutment Impressions on pages 74-79 for the Pick-Up or Transfer Technique.

2. Laboratory
undefined Follow the steps on page 81 and 82 for fabrication of the verification index, baseplate and wax occlusal rim, wax try-in and plaster or silicone matrix.

or

Request a CAM StructSURE™ Precision Milled Bar. See CAM StructSURE Manual (ART861)

3. undefined Carefully remove the Standard Abutment Gold or Castable Cylinders from the verification index. Place the cylinders onto the analogs and attach with waxing screws using a .048” Large Hex Driver. Adjust the height of the sleeves as necessary. Wax the hybrid bar patterns to the waxing sleeves and add acrylic resin retention to the top of the bar. Use the matrix on the cast to position the bar within the confines of the wax try-in.

4. undefined Remove the hybrid bar wax up from the cast. Invest, burnout and cast the bar in a semi-precious or high noble alloy (see page 9 for casting alloy specifications). Divest, finish and polish the under surface of the bar with polishing protectors in place. Return the bar to the restorative dentist for try in and fit verification.

undefined

undefined

(continued on next page)

 

 

 

 

 
 