A definitive impression was made of the
Encode Healing Abutments. The abutments were removed and
implant temporary cylinders were placed into the internal
interface of the implants. The temporary cylinders were
adjusted for interocclusal clearance and picked up inside the
laboratory processed provisional FPD. Ideal emergence profiles
were developed and the provisional FPD was secured with
abutment screws torqued to 20Ncm. The provisional restoration
had minimal occlusal contacts in centric occlusion. Lateral
contacts were eliminated (Figures 6 and 7).
Figure 6
Figure 7
Figure 8
Osseointegration was evaluated by applying 32Ncm of reverse
torque to the implants. The patient did not experience any
discomfort with this procedure and macroscopic movement was
not seen. The implants were considered to be osseointegrated.
Impression copings were placed into the internal interface of
the implants (Figure 9) and an implant level impression was
made. New implant temporary cylinders were placed into the
implants and a verification index was made with
autopolymerizing acrylic resin (Figures 10 and 11). A new
fixed provisional restoration was made with a PreFormance
Temporary Cylinder to incorporate the implant in site #3
(Figure 12).
Figure 9
Figure 10
Figure 11
Figure
12
Anatomic emergence profiles were developed in the
laboratory with autopolymerizing acrylic resin (Figure 13).
This prosthesis included natural teeth #’s 2 and 7 (Figures 14
and 15).